Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 98 Install 1-3 stop unit Date: November 19, 2015 Contractor: Thyssenkrupp Permit type: Moving equipment | Permit status: Permit issued | Expiration date: May 19, 2016 | Current use: Business use | Permit id: 15-35081-Movg | |||||
Renovate existing green-rated building and brown-rated courtyard infill, and construct new fourth floor penthouse on brown-rated portion as follows, per application received 03/24/15 and drawings stamped vcc approved 09/10/15:remove existing elevator penthouse, repair roof to match existing,remove existing brown-rated rear roof structure,remove existing fire escape and ladder on chartres street facade,repair facade as indicated, repair stucco as needed using vcc mortar mix,construct new penthouse with low-slope roof, conti street side patio, and stucco finish, install nine (9) new hvac units on low-slope roof of penthouse, with metal louvered screening, roof access hatch, and life-safety required rail. Millwork drawings must be submitted to the vcc for review, approval and permitting prior to installationnote: revision added by vcc on sheet a2. 2, detail 9, states: "detail to read saw cut within mortar joing, between brick wythes, and insert flashing into a continuous bed of sealant." Date: March 24, 2015 Permit type: Vcc general work | Permit status: Permit approved | Current use: Business use | Permit id: 15-08805-Vcgen | |||||
Renovate existing green-rated building and brown-rated courtyard infill, and construct new fourth floor penthouse on brown-rated portion as follows, per application received 03 24 15 and drawings stamped vcc approved 09 10 15:remove existing elevator penthouse, repair roof to match existing,remove existing brown-rated rear roof structure,remove existing fire escape and ladder on chartres street facade,repair facade as indicated, repair stucco as needed using vcc mortar mix,construct new penthouse with low-slope roof, conti street side patio, and stucco finish, install nine (9) new hvac units on low-slope roof of penthouse, with metal louvered screening, roof access hatch, and life-safety required rail. Millwork drawings must be submitted to the vcc for review, approval and permitting prior to installationnote: revision added by vcc on sheet a2. 2, detail 9, states: "detail to read saw cut within mortar joing, between brick wythes, and insert flashing into a continuous bed of sealant." Date: March 24, 2015 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: May 10, 2017 | Current use: Business use | Permit id: 15-08805-Vcgen |